These are the questions buyers ask most often when specifying, installing and running X-ray screening equipment. Each answer is taken from our technical articles, where the full context is available.
A single-energy scanner produces one attenuation image. A dual-energy scanner compares high- and low-energy attenuation to estimate effective atomic number, which lets it colour-code organic, inorganic and metal materials.
For security screening where material discrimination matters (airports, courts, parcel), yes: the operator can separate organic threats from metal clutter. For industrial inspection of a single known material, single energy is often sufficient.
No. It sorts material into atomic-number bands and colours; identifying a specific device still depends on the operator or on automatic threat-detection software.
Measure the largest item you must scan. A 60x40 cm tunnel handles cabin bags, 100x80 cm handles hold baggage, and 150x180 cm covers palletised cargo.
Oversized items have to be scanned elsewhere or checked manually, which creates a bottleneck at peak times and often forces the purchase of a second machine.
Not directly; throughput depends on belt speed and operator handling. But large tunnels cost more and need more floor space and power.
Two generators and two detector arrays produce two images from different angles, so an object hidden behind dense material in one view is visible in the other.
At high-throughput checkpoints where operators cannot afford to re-scan bags, and in applications with dense clutter such as tools, electronics or mixed cargo.
No. It reduces re-scans and improves confidence, but suspicious items still require opening or secondary screening.
Fixed systems suit a dedicated gate with stable throughput and available civil works. Mobile systems suit multiple sites, temporary checkpoints, or locations where construction is impossible.
Typically a few trucks per hour depending on the drive-through procedure, which is lower than a fixed portal with a conveyor or a drive-through arch.
A shielded building or pit, power, a radiation-controlled area and often civil approval, which is why lead times are much longer than for mobile units.
To inspect the underside of vehicles for contraband, explosives or stowaways without a manual check, typically at checkpoints and facility entrances.
Most systems require the vehicle to pass at low speed, a few kilometres per hour, so the imaging line captures a complete and undistorted underside image.
Lighting, road surface condition and camera cleanliness. A wet or dirty road surface produces the most misleading images.
For suspected packages, improvised devices or inaccessible objects where moving the item is unsafe, and for field inspection where a cabinet system cannot be brought in.
It uses a separate generator and detector panel with the operator at a distance, so it requires a controlled area and radiation safety procedures rather than shielding inside a box.
Radiation safety training, an understanding of the controlled area and image interpretation practice. In many jurisdictions an operator licence is required.
Tunnel size and belt load, generator power and energy range, detector type and resolution, required certifications, throughput, site conditions such as power and floor loading, the acceptance test method and operator training.
Because they copy another project parameters without stating the screening requirement, so suppliers quote a machine that meets the numbers but not the threat profile.
Throughput depends on operator handling as much as on belt speed, so specify belt speed and expected bags per hour separately and test both at acceptance.
Mechanical installation and levelling, electrical safety, detection of the standard test piece in every zone, a false-alarm check with common items, and a documented calibration record.
The buyer security or facility manager together with the supplier engineer, with results written into an acceptance report signed by both parties.
Zone sensitivity and baseline must be re-calibrated. If it still fails, the receiver or zone coil may be faulty and the unit should be replaced rather than accepted.
Image quality and wire detection, throughput, safety interlocks and leakage, plus verification of the specified functions against the purchase order.
Enough to cover every shift plus a backup, otherwise the machine is effectively unavailable during leave or staff turnover.
Typically annually, and always after a software upgrade or a change in the threat profile being screened.
Daily checks cover the belt, emergency stop and image quality. Monthly work covers cleaning of detector arrays and cooling, and an annual service should include image calibration and a leakage measurement.
Dirty detector arrays and cooling filters, drifting detector gain, and ageing X-ray tube output rather than the electronics.
Daily and monthly items can be done by trained site staff. Image calibration and leakage measurement should be done by the supplier or a qualified service provider.
A walk-through with the test piece to confirm detection, a check that the display and alarms work, and a visual check for damage or obstruction near the gate.
Typically annually, or whenever the surrounding environment changes, and always after any repair or relocation.
New metal objects near the gate, a shifted baseline after a power interruption, or electronic interference from equipment switched on nearby.
Using a test piece that represents the prohibited item, walking it through each zone at the intended speed, then raising sensitivity until the test piece is caught while everyday items are not.
Because the electromagnetic environment changes: nearby metal structures, moving equipment or a different floor can shift the baseline the gate learned at commissioning.
Up to a point. Beyond that the false-alarm rate makes staff ignore alarms, which is worse than missing a marginal detection.
Orange and brown for organic material, green for inorganic material such as glass and ceramics, and blue or black for metal. The exact palette depends on the manufacturer.
Dense clutter, overlapping objects, very thick metal sections and poor image calibration, all of which hide shape or distort the colour coding.
Initial classroom and simulator training plus supervised screening. Competence is maintained by refresher training and regular test-image exercises.
Leakage from a properly shielded cabinet is well below regulatory limits, typically under 1 microsievert per hour at 5 cm from the surface, and the useful beam is fully enclosed.
Yes for cabinet systems: the dose to a nearby person is negligible compared with natural background. Open-beam systems require a controlled area and operator training.
A leakage survey around the cabinet, door interlocks, warning labels and the emergency stop function. These normally form part of the acceptance test.
At minimum CE for the European Union and FDA registration for the United States. Many buyers also ask for ISO 9001 and a radiation safety test report.
No. Clearance depends on the destination import rules, which may require local registration, a radiation licence or a test report from an accredited laboratory.
A CE technical file built on existing test reports can take weeks. New EMC and radiation testing plus FDA review can take several months.
They target different materials: ferrous and non-ferrous metal, electronic devices, and copper, silver or gold respectively. The sensing principles differ, which is why one cannot substitute for another.
18 zones is adequate for most entrances. 24 zones locates the metal more precisely and speeds up secondary screening.
Because it detects metal, not threats. Sensitivity has to be calibrated on site so everyday items are filtered while prohibited items are still caught.
It can, and at high sensitivity it will. Sites that only care about phones usually accept a short list of "expected" alarms and train staff to ignore those.
On multi-zone gates yes, and it is the main tool for reducing nuisance alarms — set the pocket and bag zones higher, keep the feet zone lower.
No. Detection is based on the device's physical signature, so a switched-off phone is still found. That is why phone detectors are used in exam halls.
Check for a second device — a smart watch, a tablet in a bag, or a medical implant. If none, recalibrate; the baseline may have drifted after a nearby metal object was moved.
It depends on the risk profile. Hospitals usually need to keep weapons out of emergency departments, while schools often need phone detection rather than metal detection.
If the goal is preventing phones, a phone detection gate. A metal detector alarms on keys and buckles and cannot reliably distinguish phones.
A single walk-through gate can be installed and calibrated in a few hours. The main work is site preparation: power, a level floor and clearance from metal structures.
Metal, glass, stone, bone, high-density plastic and some rubber, meaning contaminants that differ from the product in density or atomic number.
Low-density contaminants that resemble the product, such as a soft plastic fragment inside a dense product. It also cannot detect chemical or microbiological contamination.
No. Inspection doses are far below the level that changes food properties, and the product does not become radioactive.
Metal detectors are cheaper and sufficient when only ferrous and non-ferrous metal are risks. X-ray is needed when glass, stone, bone or dense plastic are also risks.
It can, but X-ray costs more and is usually placed where the wider contaminant range justifies it, often after the metal detector rather than instead of it.
Metal detectors cannot. X-ray detection of low-density plastic depends on the density difference from the product, so some fragments remain undetectable.
It splits the attenuation spectrum into seven bands and assigns a colour to each, giving a finer material gradient than the usual three-colour organic, inorganic and metal scheme.
Ore and mineral sorting where small differences in effective atomic number matter, and security screening where organic explosives sit close to common plastics in density.
No. It gives a fast visual and semi-quantitative indication. Final grade determination still requires sampling and assay.
For fast, high-resolution views of a specific plane or solder joint. CT is needed when the defect is internal and its position in depth is unknown.
Micron-level feature resolution depending on the tube spot size and geometric magnification, which is why the sample is placed close to the source.
Yes. CT requires hundreds of projections and reconstruction, so a single scan can take minutes versus seconds for a 2D image.
Three tiers: compact dual-energy scanners for hand baggage, checkpoint scanners with a larger tunnel for cabin baggage at high throughput, and large-tunnel machines for hold baggage, oversize items and cargo.
Dual-energy classifies material by atomic number; dual-view adds a second angle so overlapping objects can be separated. Busy checkpoints usually want both.
CE, RoHS and FDA certification plus China Ministry of Public Security approval. Airport acceptance is decided by the local regulator, and the factory supplies test reports and radiation-safety documentation.
Start with the buying guide for the four configuration decisions, then check the price guide to understand what drives cost before comparing quotations.