A walk-through detector is a single integrated unit: six steps and about twenty minutes to assemble. But assembled is not the same as accepted. Eight checks decide whether the gate is usable, and two of them — no alarm on an empty pass, and a clean alarm on the sample — determine whether any later tuning means anything.
The design is integrated, so a practised team can assemble or dismantle a gate in about twenty minutes.
| # | Check | Pass condition |
|---|---|---|
| 1 | Vertical and stable | Stands vertical, does not rock when pushed, foot covers fitted |
| 2 | Panel orientation | Left and right fitted per the markings |
| 3 | Probe leads | Both seated; a light pull does not detach them |
| 4 | Self-test | Reaches the working screen after about one minute, no errors |
| 5 | People counting | Single pass increments by one; ten consecutive passes count correctly |
| 6 | Empty pass | A person carrying no metal passes without an alarm |
| 7 | Sample pass | The chosen sample alarms, with the correct zone indicated |
| 8 | Alarm reset | After the alarm stops, the next person passes normally without a repeat alarm |
Checks 6 and 7 are the reference points for sensitivity: no alarm when empty, a clean alarm on the sample. If either fails, do not start changing parameters.
| Item | Value |
|---|---|
| Passage size | 1990 × 700 × 500 mm (H × W × D) |
| Overall size | 2220 × 815 × 500 mm |
| Net weight | about 60 kg |
| Power | 220–240 V, 50/60 Hz |
| Consumption | under 30 W |
| Operating temperature | -25 °C to +55 °C |
| Throughput | over 60 people per minute |
| Construction | PVC composite panels, waterproof foot covers |
Probe lead not seated. Shows up as "does not count" or "one zone never alarms". Pull each lead lightly after assembly.
Panels swapped. Invisible from outside, but transmit and receive are reversed and sensitivity drops noticeably.
Installed in a draught or beside a roller shutter. The gate moves, the alarm never settles. No parameter fixes this.
Uneven floor. The four feet carry different loads, the gate sways slightly as people pass, and the result is an intermittent alarm that is very hard to diagnose.
It alarms constantly after installation. Run check 6 first. If an empty pass alarms, it is siting or stability, not sensitivity — measure the distances, check for draughts, check the floor.
It alarms but does not count. Infrared problem: check the panel leads, then look for interference near the sensors (cameras, remote controls, direct sun), then replace the sensor.
Can it be installed outdoors? The panels are weather-treated, but a canopy is strongly recommended, and the sensors must be out of direct sun and draughts.
Do we need the factory to commission it? The checklist is usually enough. If three or more of the eight checks fail, call the factory — it is almost always an installation issue.