Walk-through detector maintenance comes down to four things: a start-of-shift self-check, weekly cleaning, monthly verification and an annual validation. What decides whether the gate is dependable is not the frequency but whether each check is recorded — without records you cannot later prove whether the equipment failed or the procedure was skipped.
All four must pass before the gate is used for screening. If any fails, work through the troubleshooting order — do not wave people through.
| Symptom | Likely cause | Action |
|---|---|---|
| Does not count people | Loose probe lead; blocked or disturbed infrared; direct sunlight | Reseat leads → clear interference → replace the sensor |
| Frequent false alarms | Metal within 1.5 m; gate swaying; sensitivity too high | Measure distances → stabilise or relocate → lower sensitivity with the sample method |
| One zone never alarms | Zone sensitivity set to zero; indicator or detection board fault | Check the zone parameter → inspect the corresponding column |
| Alarm does not stop | Alarm duration too long; someone standing inside the gate | Shorten audio/LED alarm time → enforce one-at-a-time passage |
| Screen frozen or abnormal | Unstable supply, static, main board fault | Power cycle → check voltage → contact the factory |
| Alarms but no metal found | Belt buckle, steel-toe boots, medical implant, metallic thread clothing | Confirm with a handheld detector → review the dress code |
The environment changes. Meeting the 2 m and 5 m distances at installation does not mean the site still complies six months later. A new inverter air conditioner or a roller shutter next door starts a false-alarm problem.
Sensitivity gets "helpfully" raised. Someone on a later shift decides the gate is too quiet and turns sensitivity up; false alarms spike and guards start ignoring the gate. Keep the password controlled and log every parameter change.
Records matter more than maintenance. If a missed detection is disputed a year later, the only evidence is the self-check log and the parameter-change log. No records means no maintenance, in practice.
Does it really need a minute after power-on? Yes. The self-test takes about a minute to reach optimum detection state; screening before that risks missed detection.
Is alcohol safe for cleaning? Yes, on a cloth, sparingly. Do not use strong solvents such as thinner — they attack the panel surface.
How often should the factory visit? Once a year for full validation under normal use; call them when there is a hardware fault such as a main board or detection board failure.
Can we dismantle and move it ourselves? Yes — it is an integrated design and takes about twenty minutes. After any move, repeat the empty-pass and sample checks.
Installation and the eight acceptance checks · Setting detector sensitivity · Comparing the five detector types
Products: FJ-WT18 metal detector gate · copper, silver and gold gate · mobile phone detection gate
Want advice for your own site? Tell us what you inspect, the daily volume and the site conditions — we will propose an approach before proposing a product.