Walk-Through Detector Maintenance Checklist: Shift, Week, Month, Year

2026.11.16

Short answer

Walk-through detector maintenance comes down to four things: a start-of-shift self-check, weekly cleaning, monthly verification and an annual validation. What decides whether the gate is dependable is not the frequency but whether each check is recorded — without records you cannot later prove whether the equipment failed or the procedure was skipped.

Every shift: a five-minute self-check

  1. Power-on self-test — wait about a minute for the unit to reach the working screen with no errors
  2. Empty pass — walk through carrying no metal; any alarm means interference or an unstable gate
  3. Sample pass — pass your fixed sample (a bunch of keys or a dedicated test piece); it must alarm and show the correct zone
  4. Count check — one pass increments by one, two consecutive passes by two

All four must pass before the gate is used for screening. If any fails, work through the troubleshooting order — do not wave people through.

Weekly: clean and tighten

  • Wipe the panels inside and out with a cloth dampened with water or alcohol, paying attention to the infrared sensors; no other solvents
  • Check the four foot covers for movement and the bolts for slack
  • Pull each panel probe lead lightly to confirm it is seated
  • Check the zone indicator columns for dark segments
  • Record the week's false alarms and their causes

Monthly: verify and reconcile

  • Repeat the sample method: the sample still alarms, an empty pass still does not
  • Confirm global and zone sensitivity have not been changed, with the password holder
  • Check the operating frequency against adjacent equipment
  • Export or transcribe the people count and alarm count, and reconcile with the site log
  • Inspect the supply cable, plug and earthing

Annually: full validation

  • Run a complete detection-capability test with standard test pieces and archive the results
  • Inspect the structure, welds and ageing of the foot covers
  • Verify infrared response and counting accuracy
  • Re-check the installation environment for new roller shutters, lifts or heavy equipment
  • Update the equipment file: installation date, repairs, consumable replacements

Common faults and fixes

SymptomLikely causeAction
Does not count peopleLoose probe lead; blocked or disturbed infrared; direct sunlightReseat leads → clear interference → replace the sensor
Frequent false alarmsMetal within 1.5 m; gate swaying; sensitivity too highMeasure distances → stabilise or relocate → lower sensitivity with the sample method
One zone never alarmsZone sensitivity set to zero; indicator or detection board faultCheck the zone parameter → inspect the corresponding column
Alarm does not stopAlarm duration too long; someone standing inside the gateShorten audio/LED alarm time → enforce one-at-a-time passage
Screen frozen or abnormalUnstable supply, static, main board faultPower cycle → check voltage → contact the factory
Alarms but no metal foundBelt buckle, steel-toe boots, medical implant, metallic thread clothingConfirm with a handheld detector → review the dress code

Three things people overlook

The environment changes. Meeting the 2 m and 5 m distances at installation does not mean the site still complies six months later. A new inverter air conditioner or a roller shutter next door starts a false-alarm problem.

Sensitivity gets "helpfully" raised. Someone on a later shift decides the gate is too quiet and turns sensitivity up; false alarms spike and guards start ignoring the gate. Keep the password controlled and log every parameter change.

Records matter more than maintenance. If a missed detection is disputed a year later, the only evidence is the self-check log and the parameter-change log. No records means no maintenance, in practice.

A simple record sheet

  • Date, shift, and whether all four self-checks passed
  • People count, alarm count and secondary-check count for the week
  • Whether parameters changed, and by whom
  • Any abnormality and how it was resolved

FAQ

Does it really need a minute after power-on? Yes. The self-test takes about a minute to reach optimum detection state; screening before that risks missed detection.

Is alcohol safe for cleaning? Yes, on a cloth, sparingly. Do not use strong solvents such as thinner — they attack the panel surface.

How often should the factory visit? Once a year for full validation under normal use; call them when there is a hardware fault such as a main board or detection board failure.

Can we dismantle and move it ourselves? Yes — it is an integrated design and takes about twenty minutes. After any move, repeat the empty-pass and sample checks.